Published by the team at Cloverdale HVAC

A close-up of an air conditioner nameplate with efficiency ratings in Montgomery, AL

SEER2, HSPF2 and AFUE Explained

SEER2, HSPF2, and AFUE are the three numbers on a heating and cooling quote. This guide explains each one in plain words, with the real minimums for Alabama, so the quote means something before you approve it.

  • ✓21-point audit in full
  • ✓Call direct, no forms to fill
  • ✓Serving Montgomery, Prattville & Wetumpka

What is SEER2, and what does it mean for my quote?

SEER2 is the seasonal efficiency rating for air conditioners and heat pumps, tested under the current test method. It says how much cooling you get for each unit of electricity across a season.

The number alone does not set your bill. The ducts, the sizing, and the installation matter as much as the rating. A high SEER2 on a badly sized system will not save what the label promises.

  • SEER2: seasonal cooling efficiency, tested under the current test method.
  • Higher SEER2: less electricity for the same cooling.
  • The number alone does not set your bill. Ducts, sizing, and installation matter as much.
  • Our page on AC installation in Montgomery covers sizing alongside the rating.
An air conditioner nameplate showing efficiency ratings in a Montgomery, AL home
An air conditioner nameplate in Montgomery, AL: what is SEER2.

What is the SEER2 minimum in Alabama?

Montgomery is in the Southeast region, and the minimum for a split air conditioner under 45,000 Btu/h is 14.3 SEER2. Larger split systems sit at 13.8 SEER2. The table below gives the full picture, because a single number on its own is a slogan, not a guide.

Split heat pumps sit at 14.3 SEER2 with 7.5 HSPF2, and single-package systems sit at 13.4 SEER2. The minimum is a floor, not a target.

  • Southeast split AC under 45,000 Btu/h: 14.3 SEER2.
  • Southeast split AC 45,000 Btu/h and up: 13.8 SEER2.
  • Split heat pump: 14.3 SEER2 and 7.5 HSPF2.
  • Single-package systems: 13.4 SEER2.
  • The minimum is a floor, not a target.
A table of SEER2 minimum ratings for Alabama, with the Southeast region highlighted
SEER2 minimum ratings for Alabama: what is the SEER2 minimum.

SEER2 and HSPF2 minimums: the full table

Montgomery sits in the Southeast region for split air conditioners, and in IECC Climate Zone 3.

System typeSEER2 minimumHSPF2 minimumRegion
Split air conditioner, under 45,000 Btu/h14.3Not rated for heatingSoutheast
Split air conditioner, 45,000 Btu/h and up13.8Not rated for heatingSoutheast
Split heat pump14.37.5National
Single-package air conditioner13.4Not rated for heatingNational
Single-package heat pump13.46.7National

What is HSPF2?

HSPF2 is the seasonal heating efficiency rating for heat pumps, tested under the current test method. It says how much heat you get for each unit of electricity across a heating season. The minimum for a split heat pump is 7.5 HSPF2, and for a single-package heat pump it is 6.7 HSPF2.

It matters most in a Montgomery winter, because it sets how much heat the pump pulls from cold air, and how often auxiliary heat has to help. On the coldest nights, down to 14-18°F, the pump leans on auxiliary heat, and that is normal.

  • HSPF2: seasonal heating efficiency for heat pumps.
  • Split heat pump minimum: 7.5 HSPF2.
  • Single-package heat pump minimum: 6.7 HSPF2.
  • Auxiliary heat: normal on the coldest nights, and a higher HSPF2 leans on it less often.
A heat pump outdoor unit running in cold weather in Montgomery, AL
A heat pump outdoor unit in cold weather in Montgomery, AL: what is HSPF2.

What is AFUE?

AFUE is the annual fuel efficiency rating for furnaces, and it says how much of the gas becomes heat in your home. The federal floor for a non-weatherized gas furnace is 80% AFUE.

A condensing furnace sits around 90-98% AFUE, because it recovers heat from the exhaust that a standard furnace sends up the flue. The 95% figure is not today's minimum: a federal rule that would have set it for furnaces built from late 2028 is unsettled.

  • AFUE: annual fuel efficiency for furnaces.
  • Federal floor: 80% AFUE for a non-weatherized gas furnace.
  • Condensing furnace: around 90-98% AFUE.
  • 95% AFUE is not today's minimum: the rule that would have set it is unsettled.
  • Our page on furnace installation in Montgomery covers the tiers alongside sizing.
A furnace AFUE efficiency label in a Montgomery, AL home
A furnace AFUE label in Montgomery, AL: what is AFUE.

What does the rating mean when you get a quote?

It means three things: the rating on the quote, the size from the load calculation, and the ducts. A high SEER2 on a badly sized system will not save what the label promises, and leaky ducts will lose the cooled air before it reaches the rooms. Ask for all three together, in writing.

The load calculation uses Montgomery design temperatures: 27°F for heating and 93°F dry-bulb with 76°F wet-bulb for cooling. A system sized from square footage alone is a guess.

  • Rating: SEER2, HSPF2, and AFUE, named on the quote.
  • Size: from a load calculation, not from square footage alone.
  • Ducts: checked for leakage before the rating is trusted.
  • Design temperatures: 27°F heating, 93°F dry-bulb and 76°F wet-bulb cooling.
  • When the rules disagree: our page about repair or replace works the decision.
An HVAC technician explaining a quote with efficiency ratings to a homeowner in Montgomery, AL
An HVAC technician explaining a quote in Montgomery, AL: what the rating means when you get a quote.

Your questions, answered

SEER2 is the seasonal efficiency rating for air conditioners and heat pumps, tested under the current test method. A higher SEER2 means less electricity for the same cooling, but the number alone does not set your bill. The ducts, the sizing, and the installation matter as much as the rating, so read the number with the quote.

Montgomery is in the Southeast region, and the minimum for a split air conditioner under 45,000 Btu/h is 14.3 SEER2. Larger split systems sit at 13.8 SEER2. Split heat pumps sit at 14.3 SEER2 with 7.5 HSPF2, and single-package systems sit at 13.4 SEER2. The full table is on this page.

HSPF2 is the seasonal heating efficiency rating for heat pumps, tested under the current test method. The minimum for a split heat pump is 7.5 HSPF2, and for a single-package heat pump it is 6.7 HSPF2. It matters most in a Montgomery winter, because it sets how much heat the pump pulls from cold air.

AFUE is the annual fuel efficiency rating for furnaces, and it says how much of the gas becomes heat in your home. The federal floor for a non-weatherized gas furnace is 80% AFUE. A condensing furnace sits around 90-98% AFUE, because it recovers heat from the exhaust. The 95% figure is not the minimum today.

It means three things: the rating on the quote, the size from the load calculation, and the ducts. A high SEER2 on a badly sized system will not save what the label promises, and leaky ducts lose the cooled air before it reaches the rooms. Ask for all three together, in writing.

Not always. A higher SEER2 costs more up front, and the saving depends on how much you run the system, how well the ducts hold air, and how the system was sized. In a home that runs cooling from late spring into fall, the saving has more hours to add up. With leaky ducts, the ducts come first.

A homeowner talking with an HVAC technician about SEER2 ratings in Montgomery, AL
A homeowner talking with a technician in Montgomery, AL: your questions, answered.

Got a quote with a rating on it? Call and check it

Call now

Have a Quote With SEER2, HSPF2, or AFUE on It? Call With the Numbers

Bring the rating, the size, and the duct check from the quote. That is enough to start the conversation.

Call About SEER2

Plan ahead

Want the Repair-or-Replace Side?

Read our page about repair or replace, the $5,000 rule and the 50% rule, worked from your written quote.

A rating is a floor, not a promise. The size and the ducts decide what it saves.

  • Montgomery design temperatures: 27°F heating, 93°F dry-bulb and 76°F wet-bulb cooling.
  • The same visit process covers Prattville homes and Wetumpka homes too.
An HVAC technician talking with a homeowner about SEER2 ratings in Montgomery, AL
An HVAC technician talking with a homeowner in Montgomery, AL: got a quote with a rating on it?

Find us

Find Cloverdale HVAC in Montgomery

Cloverdale HVAC 714 E Main St, Prattville, AL 36067.

Get Help NowServices