Heat Pump Repair in Montgomery, AL
Defrost or fault? Steam, ice, or aux heat that will not quit. Call, describe what you see, and get a written price first.
- ✓21-point audit in full
- ✓Call direct, no forms to fill
- ✓Serving Montgomery, Prattville & Wetumpka
ANSWER FIRST
Does your heat pump need repair?
Yes, if the heat pump will not heat or cool, the outdoor unit is coated in thick ice that never clears, the system is stuck in defrost, or the aux heat runs for hours in mild weather. Steam rising from the outdoor unit on a cold morning is normal. Thick ice that stays, and a unit that never finishes defrost, are not.
Heat pumps are the most common system in Montgomery homes, and they heat and cool from the same outdoor unit. Montgomery design heating is 27 degrees, so a heat pump sized for the house works through most of the winter. When it cannot keep up, the backup heat steps in, and the next sections explain when that is normal and when it is a fault.

NORMAL VS FAULT
What is normal, and what is a fault?
Defrost is normal. On cold, damp days frost builds on the outdoor coil, and every 30 to 90 minutes the system briefly runs in reverse to melt it. During defrost you may see steam or vapor rising off the outdoor unit, and the indoor air may feel cooler for a few minutes. The aux heat runs during defrost to temper the air. That is the system working as designed.
A fault looks different. The whole outdoor unit encased in ice, frost that never clears, a system that seems stuck in defrost, or a fan that will not run are faults. So is warm air in summer that never cools, and cold air in winter that never warms. If the whole unit is coated in ice, turn the system off at the thermostat and call. Do not chip ice off the unit, and do not pour hot water on it.
Heat pump air feels warm, not hot, and flows longer and more gently than furnace air. If the house stays at the temperature you set, it is working.

| What you see | Normal, or a fault? |
|---|---|
| Steam or vapor rising from the outdoor unit on a cold morning | Normal. Melting frost during defrost, not smoke |
| Light frost on the outdoor coil that clears after a few minutes | Normal. The defrost cycle melting frost off the coil |
| Thick ice coating the whole outdoor unit, or frost that never clears | Fault. Turn the system off at the thermostat and call |
| System stuck in defrost, or switching back and forth without heating | Fault. The defrost board or reversing valve needs a technician |
| AUX HEAT showing on cold nights, or briefly during defrost | Normal. Backup heat helping the heat pump, or tempering the air in defrost |
| AUX HEAT running for hours when it is mild outside | Fault. The heat pump is not carrying the load, and the strips are doing its work |
SAFE CHECKS
What can you safely check?
Work through these in order, and stop at anything involving refrigerant, electrics, or opening the unit.
- Thermostat: set it to HEAT in winter or COOL in summer, the temperature a few degrees from the room temperature, and the fan to AUTO. Check that it is not set to EM HEAT by mistake. Emergency heat runs the backup strips alone, with the heat pump off, and costs far more to run.
- Filter: hold it up to the light. If you cannot see light through it, it is overdue. Replace it with the same size and type.
- Outdoor unit: look from a distance and clear leaves, grass cuttings, and debris from around it. Make sure plants are not pressed against it. Do not open it, hose inside it, or touch wiring.
- Breaker: if the heat pump breaker has tripped, switch it back on once. If it trips a second time, leave it off.
- Setpoint jumps: if you raised the thermostat by 5 degrees or more, the aux heat will run to close the gap. That is normal. Set the temperature in small steps instead.
- Ice: if the whole outdoor unit is encased in ice, turn the system off at the thermostat and call. Do not chip at the ice.

COMMON FAILURES
What usually fails?
The parts that fail most often are the same short list. The reversing valve switches the system between heating and cooling, and when it sticks the heat pump heats when it should cool, or cools when it should heat. The defrost board runs the defrost cycle, and when it fails the coil ices over or the system stays stuck in defrost.
The compressor moves the refrigerant, and when it fails the system runs but gives no heat and no cooling. The capacitor starts the fan and compressor motors, and a failed capacitor leaves the unit humming or clicking with no start. Low refrigerant from a leak drops capacity, so the heat pump cannot reach the setpoint and the thermostat locks in aux heat. A sealed system does not use up refrigerant, so low charge means there is a leak.
Aux heat is not a failure on its own. It is the backup heat that turns on to help the compressor hold your setting, and both the aux heat and the compressor may run at the same time. It is normal below the balance point, the outdoor temperature where the heat pump can no longer carry the house alone, during defrost, or after a big setpoint jump. The warning sign is aux heat in mild weather, above about 40 degrees, for hours. That points at a dirty filter, a refrigerant leak, or a failed sensor, and it is worth a call.
Emergency heat is different. It is a manual setting that runs the backup strips alone, with the compressor off, and it is meant for when the outdoor unit has failed. If you did not switch it on, set the thermostat back to HEAT.

| Part | Symptom it causes | What the technician checks |
|---|---|---|
| Reversing valve | Heats when it should cool, or cools when it should heat | Whether the valve has stuck, and whether the thermostat signal reaches it |
| Defrost board | Coil ices over, or the system stays stuck in defrost | The board, the defrost sensor, and the defrost cycle timing |
| Compressor | System runs but gives no heat and no cooling | Power reaching the unit, the capacitor, and the refrigerant level |
| Capacitor | Unit hums or clicks with no start | Whether the capacitor has failed, and whether the motors it starts are still in good order |
| Refrigerant leak | Weak heating and cooling, aux heat running in mild weather | The leak is found and repaired, then the system is recharged, all technician-only work |
| Thermostat | Aux heat running too often, or the wrong mode set | The settings, the wiring, and whether the heat pump stages are set right for Montgomery |
REPAIR OR REPLACE
Should I repair or replace my heat pump?
Work the two rules from your written quote. $5,000 rule: system age in years times repair cost. Past $5,000, replacement is usually the smarter move. 50% rule: repair over half the replacement cost, and replacement is usually smarter.
What failed matters. A capacitor or a defrost board is a single part, while a compressor or reversing-valve failure on an older unit is the replacement decision. A heat pump that needs a compressor on a system past 10 years is worth pricing as a replacement, with the new SEER2 and HSPF2 ratings on the quote.
Carrier puts heat pumps at 10 to 15 years, and the U.S. Department of Energy puts a heat pump at 15 to 20 years, but age alone never decides. If replacement is the smarter move, our page on heat pump installation in Montgomery covers sizing, SEER2 and HSPF2, and dual-fuel options. Homes with a gas furnace as backup should also read our page on furnace repair in Montgomery, because a dual-fuel fault can sit on either side.

THE VISIT
What happens on a heat pump repair visit in Montgomery?
Book
Say what the heat pump is doing, whether the outdoor unit has ice, and whether AUX HEAT or EM HEAT shows on the thermostat. The technician confirms when the visit will happen during that call.
Inspection and Diagnosis
The technician examines the outdoor unit, the indoor coil, the refrigerant charge, and the thermostat settings to find the fault.
Repair or Replacement
The technician explains the fault in plain words, and talks you through what the repair will involve. Before any work begins, get the repair figure in writing, and the replacement figure next to it if a new heat pump is genuinely an option. Work starts only after you approve it.
Safety Check
Once the repair is in, the system is run in both heating and cooling and checked. The technician verifies warm air in heating, cold air in cooling, and airflow at the vents before leaving.
A maintenance visit follows the same pattern. It covers the heat pump in the 21-point audit in full on our maintenance plan page: filter, coils, refrigerant charge, defrost cycle, reversing valve, and aux heat check. The spring cooling check and the fall heating check both cover the heat pump, because it works in both seasons.
A heat pump loses capacity as the outdoor temperature falls, and below the balance point the aux heat makes up the difference. That is the design working, not a failure. What needs a call is aux heat doing the whole job in mild weather.

Before and after: heat pump repair in Montgomery

BeforeAfterillustrative examples only
Before and after: heat pump repair, second example

BeforeAfterillustrative examples only
READY
What to have ready when you call
Have these five details handy when you call.
- What the heat pump is doing: not heating, not cooling, or stuck in defrost.
- Outdoor unit: ice on the coil, steam rising, or the fan not running.
- Thermostat display: whether AUX HEAT or EM HEAT shows, and whether you switched it on.
- Filter condition: when it was last changed, and whether you can see light through it.
- Model and age: the brand and age of the system if you know it, and whether it is a dual-fuel pair with a gas furnace.
QUESTIONS
What do Montgomery homeowners ask about heat pump repair: steam, ice, and aux heat?
Steam rising from the outdoor unit is usually just melting frost during defrost. The heat pump briefly runs in reverse to clear frost off the outdoor coil, and the aux heat tempers the air inside. It is normal on cold, damp days. Thick ice that stays is a fault, not defrost.
It may be a thermostat set wrong, a clogged filter, a stuck reversing valve, a failed defrost board, or low refrigerant from a leak. Check the thermostat mode and the filter first, and check whether EM HEAT was switched on by mistake. If those are fine, call. Refrigerant and valve work are technician-only.
Aux heat is normal below the balance point, during defrost, or after a big setpoint jump. It is a fault when it runs for hours in mild weather, above about 40 degrees. That usually means low refrigerant, a dirty coil or filter, or a thermostat set to switch to aux too eagerly. Check the filter, then call.
Aux heat is automatic: the thermostat brings the backup strips on to help the heat pump, and the heat pump keeps running. Emergency heat is manual: you switch it on, the heat pump stops, and only the strips run. Use emergency heat only when the outdoor unit has failed, then switch back to HEAT.
Some frost is expected on cold, damp days, and the defrost cycle clears it. Heavy ice that stays means the defrost system needs attention, usually the defrost board or sensor. Turn the system off at the thermostat and call. Do not chip ice off the unit or pour hot water on it.
Work the two rules from your written quote: age times repair cost against $5,000, and repair cost against half the replacement cost. A capacitor or defrost board is a single part, while a compressor or reversing-valve failure on an older unit points to replacement. Age alone never decides.

CALL NOW
Heat pump defrosting, or broken? Call with what you see
Steam, Ice, or Aux Heat That Will Not Quit? Call Now
We fix the failed part, and the price comes in writing before any work starts. Tell us whether the outdoor unit has ice, and whether AUX HEAT or EM HEAT shows on the thermostat.
Repair or Replace? Work It From Your Written Quote
On our page about heat pump installation in Montgomery, sizing, SEER2 and HSPF2 ratings, and dual-fuel options, all on one written quote.
Homeowners describe this job in different words: heat pump repair Montgomery AL and heat pump not heating Montgomery AL all mean the same visit, with the same written price before work.
Not sure the heat pump is the problem? Start with a repair visit, and let the written quote decide whether repair or replacement is the smarter move.
- A finished heat pump job is on our projects page, before and after.
- Repair or replace? Our repair-or-replace guide works the two rules from your written quote: the $5,000 rule and the 50% rule.
- The same visit process and written-price rule apply in Prattville homes and Wetumpka homes, one rule for three cities.

Find us
Heat pump repair in Montgomery: our Prattville base
Our base is at 714 E Main St, Prattville, just off I-65 from Montgomery. Call (334) 555-0142, describe the problem, and the technician comes to you. The same visit covers heat pump repair in Montgomery homes and in Prattville and Wetumpka homes, with the same written price before work.
- Areas served: Montgomery, Prattville and Wetumpka, with the same visit process in each city.
- What to have ready: the symptom, when it started, and the system brand and age if you know it.
- How the visit works: the technician comes to your home. This address is the base the visit starts from.
Cloverdale HVAC 714 E Main St, Prattville, Alabama 36067, USA (334) 555-0142